Brief Description:
MTL 451 BL D2- ATEX EXPLOSION PROOF INDUSTRIAL VACUUM CLEANER
Description:
NFPA 652 COMPLIANT ATEX EXPLOSION PROOF ETL CERTIFIED FOR CLASS II, DIVISION 2 INDUSTRIAL VACUUM CLEANER
Features:
  • Complete steel construction Compact and mobile
  • Easy filter replacement
  • Stainless steel AISI304 collection tank Earth grounding
  • Spark-free brushless motor (average 15.000-hour life expectancy)
  • 652 COMPLIANT
  • Easy to clean and to maintain
  • NRTL certification for Class II, Division 2 hazardous locations
  • Maximum safety thanks to the three levels of air filtration
  • High efficiency filtration Accessory kit included
Compiiance:
Compliant with ETL Class II Division 2
Suction Unit Overview
The motor head is equipped with a Brushless motor: the lack of carbons allows the use of the machine even in explosive hazardous areas. The motor is protected by a series of filters and it is turned on by an independent switch placed on a soundproofed and robust metal motor head. The motor head includes a vacuum gauge and tension power lights as standard.
Filter Unit Overview
The large surface star antistatic filter, located inside the filter chamber, is made of polyester and provides high resistance against clogging and passage of fine dust. It is possible to clean the filter using an integrated mechanical system: an external lever shakes the filter vertically and enables to clean the filter thoroughly and safely, maintaining constant suction performance and preventing any dispersion of dust in the environment.
Collection Unit Overview
The vacuumed material is placed inside an AISI304 stainless steel drop-down bin mounted on wheels, which makes it possible to dispose easily and safely of the vacuumed material.
Collection Unit Capacity in gallons
12
Collection Unit Capacity in liters
45
ATEX Overview
  • Designed for Dust Explosive Atmospheres: Suitable for areas where combustible dust clouds may occur under normal operating conditions.
  • Safety Features: Includes protection mechanisms to prevent the ignition of combustible dust, such as dust-tight enclosures, and may include other safety features depending on the nature of the dust and the operating environment.
  • Application: Commonly used in industries such as food processing, pharmaceuticals, wood processing, and metalworking where combustible dust is a risk.
  • Compliance: Equipment must comply with specific European standards for safety and be labeled accordingly with the CE mark and ATEX symbol, including the "2D" classification
IECEx Overview
The IECEx marking "Class 2 Div 2 Groups F and G" refers to a classification used primarily in the United States and Canada under the National Electrical Code (NEC) and the Canadian Electrical Code (CEC), but it's recognized in the context of the IECEx certification scheme for global trade. This classification is part of a system used to specify the types of hazardous substances that might be present in the environment and the level of protection required for electrical equipment used in these areas.

Class 2: This specifies that the hazardous material in the environment is combustible dust. Division 2: Indicates that the hazardous material (combustible dust in this case) is present only under abnormal conditions, such as a failure of containment systems.
Group F: Includes combustible dusts like carbonaceous dusts (coal, carbon black, coke dust, etc.) which are electrically conductive and require specific consideration for equipment safety.
Group G: Covers dusts that are not conductive, such as flour, starch, grain, wood, plastic, and chemical dusts. These dusts are more common in industries like agriculture, food processing, woodworking, and plastics. In the Context of IECEx: IECEx Scheme: An international certification scheme that provides a means of proving compliance with IEC standards for equipment used in explosive atmospheres. IECEx and NEC/CEC Compatibility: While the IECEx scheme primarily uses the Zone system (Zone 20, 21, 22 for dust atmospheres), it recognizes the Class and Division system for facilitating international trade, especially for equipment intended for markets that use this system. IECEx Certification for Class/Division: Equipment that is certified under the IECEx scheme for use in Class 2, Division 2, Groups F and G environments undergo rigorous testing and evaluation to ensure that it can safely operate in places where specific types of combustible dust are present under abnormal conditions.
Weight
121 .lbs
Width:
23 .in
Height:
53 .in
Depth:
25 .in
Country Of Origin
Italy
Input Voltage (AC)
115,230 vac
Wattage:
1100 w
Electrical Input Hertz:
50,60 hz
Electrical Motor Phase:
1
Mobility/Portability:
Wheels
Vacuum Power Method:
Corded Electrical Motor
Intended Use:
Mixed Used,Dust,Solids,Powders
Max Water Lift
90.1 .in
Max Airflow
211.9 m3/h
Suction inlet
80 mm
Noise level (EN ISO 3744)
74 dB(A)
Filter Type
Star antistatic filter, polyester - ANT M
Filter Surface Area
22 sq/ft
HEPA Filter Class (If applicable)
H14
Oil Capacity (If applicable)
0 gallons
Dry Capacity
12 gallons
Cord Length
30 ft
Filter Surface Area
22 sq/ft
Intended Use
Mixed Used,Dust,Solids,Powders
Air compressor required?
Not Required
Air compressor minimal recommended, if required (hp)
NA
Surface Diameter
420
Material Efficiency (IEC 60335-2-69)
Polyester - ANT M
Cleaning System
Manual
Discharge System
Manually detach the stainless steel AISI304 collection tank
Electrical Ingress Protection (IP Ratings)
IP 55 - Completely dust tight. Protection against low-pressure jets of water from any direction.
Hazardous Area EPL Class
II
Hazardous Area EPL Division
2
Hazardous Area EPL Group
F,G
Hazardous Area EPL Temperature Code
T6
Hazardous Area EPL Zone
22
Hazardous Area EPL Zone Group
IIIC
Hazardous Area EPL Zone Protection
Ex h
Hazardous Area EPL Equipment Protection Levels
ATEX Zones
Zone 21
ATEX Groups
Group II
ATEX Categories
MPN
MTL 451 BL D2
Options:
  • ABSOLUTE HEPA FILTER /H14 (99.995% @ 0.18 μm)
  • PTFE COATED FILTER
  • CLASS M CYCLONE FOR FILTER PROTECTION
  • STAINLESS STEEL CHAMBER
Compliance
Compliant with ETL Class II Division 2
Applications:
Suitable for industries like food, electronics, optics, and plastics.
 

Printable Files

Printable Catalog Sheets

Get The Specification Sheet.