Brief Description: MTL 451 BL D2- ATEX EXPLOSION PROOF INDUSTRIAL VACUUM CLEANER
|
Description: NFPA 652 COMPLIANT ATEX EXPLOSION PROOF ETL CERTIFIED FOR CLASS II, DIVISION 2 INDUSTRIAL VACUUM CLEANER |
Features: - Complete steel construction Compact and mobile
- Easy filter replacement
- Stainless steel AISI304 collection tank Earth grounding
- Spark-free brushless motor (average 15.000-hour life expectancy)
- 652 COMPLIANT
- Easy to clean and to maintain
- NRTL certification for Class II, Division 2 hazardous locations
- Maximum safety thanks to the three levels of air filtration
- High efficiency filtration Accessory kit included
|
Compiiance: Compliant with ETL Class II Division 2 |
Suction Unit Overview The motor head is equipped with a Brushless motor: the lack of carbons allows the use of the machine even in explosive hazardous areas. The motor is protected by a series of filters and it is turned on by an independent switch placed on a soundproofed and robust metal motor head.
The motor head includes a vacuum gauge and tension power lights as standard. |
Filter Unit Overview The large surface star antistatic filter, located inside the filter chamber, is made of polyester and provides high resistance against clogging and passage of fine dust.
It is possible to clean the filter using an integrated mechanical system: an external lever shakes the filter vertically and enables to clean the filter thoroughly and safely, maintaining constant suction performance and preventing any dispersion of dust in the environment. |
Collection Unit Overview The vacuumed material is placed inside an AISI304 stainless steel drop-down bin mounted on wheels, which makes it possible to dispose easily and safely of the vacuumed material. |
Collection Unit Capacity in gallons 12 |
Collection Unit Capacity in liters 45 |
ATEX Overview - Designed for Dust Explosive Atmospheres: Suitable for areas where combustible dust clouds may occur under normal operating conditions.
- Safety Features: Includes protection mechanisms to prevent the ignition of combustible dust, such as dust-tight enclosures, and may include other safety features depending on the nature of the dust and the operating environment.
- Application: Commonly used in industries such as food processing, pharmaceuticals, wood processing, and metalworking where combustible dust is a risk.
- Compliance: Equipment must comply with specific European standards for safety and be labeled accordingly with the CE mark and ATEX symbol, including the "2D" classification
|
IECEx Overview The IECEx marking "Class 2 Div 2 Groups F and G" refers to a classification used primarily in the United States and Canada under the National Electrical Code (NEC) and the Canadian Electrical Code (CEC), but it's recognized in the context of the IECEx certification scheme for global trade. This classification is part of a system used to specify the types of hazardous substances that might be present in the environment and the level of protection required for electrical equipment used in these areas.
Class 2: This specifies that the hazardous material in the environment is combustible dust.
Division 2: Indicates that the hazardous material (combustible dust in this case) is present only under abnormal conditions, such as a failure of containment systems.
Group F: Includes combustible dusts like carbonaceous dusts (coal, carbon black, coke dust, etc.) which are electrically conductive and require specific consideration for equipment safety.
Group G: Covers dusts that are not conductive, such as flour, starch, grain, wood, plastic, and chemical dusts. These dusts are more common in industries like agriculture, food processing, woodworking, and plastics.
In the Context of IECEx:
IECEx Scheme: An international certification scheme that provides a means of proving compliance with IEC standards for equipment used in explosive atmospheres.
IECEx and NEC/CEC Compatibility: While the IECEx scheme primarily uses the Zone system (Zone 20, 21, 22 for dust atmospheres), it recognizes the Class and Division system for facilitating international trade, especially for equipment intended for markets that use this system.
IECEx Certification for Class/Division: Equipment that is certified under the IECEx scheme for use in Class 2, Division 2, Groups F and G environments undergo rigorous testing and evaluation to ensure that it can safely operate in places where specific types of combustible dust are present under abnormal conditions. |
|
|
|
|
|
Input Voltage (AC) 115,230 vac
|
|
Electrical Input Hertz: 50,60 hz |
|
Mobility/Portability: Wheels |
Vacuum Power Method: Corded Electrical Motor |
Intended Use: Mixed Used,Dust,Solids,Powders |
|
|
|
Noise level (EN ISO 3744) 74 dB(A) |
Filter Type Star antistatic filter, polyester - ANT M |
Filter Surface Area 22 sq/ft |
HEPA Filter Class (If applicable) H14 |
Oil Capacity (If applicable) 0 gallons |
|
|
Filter Surface Area 22 sq/ft |
Intended Use Mixed Used,Dust,Solids,Powders |
Air compressor required? Not Required |
Air compressor minimal recommended, if required (hp) NA |
|
Material Efficiency (IEC 60335-2-69) Polyester - ANT M |
|
Discharge System Manually detach the stainless steel AISI304 collection tank |
Electrical Ingress Protection (IP Ratings) IP 55 - Completely dust tight. Protection against low-pressure jets of water from any direction. |
Hazardous Area EPL Class II |
Hazardous Area EPL Division 2 |
Hazardous Area EPL Group F,G |
Hazardous Area EPL Temperature Code T6 |
Hazardous Area EPL Zone 22 |
Hazardous Area EPL Zone Group IIIC |
Hazardous Area EPL Zone Protection Ex h |
Hazardous Area EPL Equipment Protection Levels |
|
|
|
|
Options: - ABSOLUTE HEPA FILTER /H14 (99.995% @ 0.18 μm)
- PTFE COATED FILTER
- CLASS M CYCLONE FOR FILTER PROTECTION
- STAINLESS STEEL CHAMBER
|
Compliance Compliant with ETL Class II Division 2 |
Applications: Suitable for industries like food, electronics, optics, and plastics. |